RoHS is the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment. This has been a standard in Europe and is now becoming a standard in the world. Not only lead, but cadium, mercury, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated diphenyl ether (PBDE) flame retardants are limited as well. |
| Specifications:
* Universal input 90VAC to 264Vac * Single 24v output @ 2.2A continuous / @3.3A peak for 30 minutes * 80% minimum efficiency under full load * Over current protection * Short circuit protection * Over Voltage protection * 100% HI-POT tested * 100% cycling BURN-IN * 122(L)*30.5(H)*60(W)mm * Operating temperature: 0 to 45 degree C * Storage temperature : -20 to +85 degree C / Humidity: 5% - 95% (Dew free) * Designed to operate under the following extreme operating condition for over 240 hours: 45+- 2 degree C temperature and 90-95% humidty. Worldwide
EMI &
SAFETY APPROVAL:
FCC, UL, cUL, TUV, CE, PSE/JET, CCC, IRAM, EK, AS/NZS, CB, BSMI, AN/NZS/ C-tick, VCCI, CISPR22 class B, CISPR24, IC |