Home > Product > Power Supplies > AC/DC Adapter > HPA-601250U3  REV: A36

Preliminary data sheet  
Last revised: Dec 20, 2017





VI
   HIGH POWER

60W Energy-efficient Fanless LCD Monitor / TV AC Adapter /
Mini ITX 12V PC Power Supply

  • Input: 100-240V AC
  • Input AC Inlet: IEC 320 3pin (Type C14) compatible
  • Output Voltage: 12V DC
  • Ratings: 5A (60W) Continuous
  • DC Cable length - 120cm
  • DC Jack Dimensions: 5.5mm (outer) / 2.5mm (inner) / 10mm (length)
  • High efficiency design with 88% minimum at normal line input and average of 25%, 50%, 75%, 100% of max load.
  • Meet DOE CEC level VI
  • No load Power Consumption :  Less then 0.21W
  • Fanless AC adapter operates in total silence.
  • UL, cUL, TUV, CE, FCC, CCC, KC, GS, CB, DOE VI, cTick, SAA Certified
  • RoHS Compliant





Technical Specifications


  • AC Input Voltage
     Maximum Voltage: 264Vac
     Normal Voltage : 100~240Vac
     Minimum Voltage: 90Vac
  • AC Input Frequency
    Maximum Frequency: 63Hz
    Normal Frequency: 50~60Hz
    Minimum Frequency: 47Hz
  • Input Current:
     1.2A (Max.) @ 115Vac input will full load.
     0.6A (Max.) @ 230Vac input will full load.
  • High efficiency design with 88% minimum at normal line input and average of 25%, 50%, 75%, 100% of max load.  Meet CEC level VI
  • No load Power Consumption :  Less then 0.21W
  • Inrush Current (cold start) : 30A Max. @110Vac/60Hz;   60A Max. @230Vac/50Hz
  • AC Leakage Current: 0.25mA Max. @240VAC input.
  • Line Regulation: This line regulation is less than 5%, of rated output voltage@ full load
  • Minimum Load: 0.0A
  • Hold Up Time: ≧ 5mSec., @ 115V AC input line, with full load.
  • Rise Time: ≦40 milli-second @ 115V AC input with full load - from 10% to 90% of output voltage.
  • Turn-ON Time: The output voltage should rise to 90% of rated output voltage in less than 3 second from 115V AC applied to start up.
  • Over voltage protection

  • Short circuit protection

  • Over Voltage Protection
  • 100% HI-POT tested: IEC 320 3pin primary to secondary 1800Vac 5mA 1min

  • 100% cycling BURN-IN under 80% load for 2 hours

  • 12V DC output @  +- 5% Standard Deviation

  • 120mV Maximum Ripple Voltage

  • Operating temperature:  0 - 50 degree C

  • Storage temperature: -20 - 80 degree C

  • Humidity : Operating -  10 to 90 %;  Storage - 5 to 90 %
  • Altitude :  Operating - From sea level to 2,000-Meter ; Storage - 5,000-Meter
  • MTBF : > 50,000 hours at full load under 25 degree C ambient condition
  • Safety compliance: UL, cUL, TUV, CE, FCC, CCC, KC, GS, CB, DOE VI, cTick, SAA
  • Dimensions: L114 * W50 * H30.5 mm

 Lead-FREE
 Cadium-
FREE
 Mercury-FREE
 Hexavalent chromium-FREE
 PBB-FREE
 PBDE flame retardants-
FREE
RoHS Compliant - made with hazardous-free components

RoHS is the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment. This has been a standard in Europe and is now becoming a standard in the world. Not only lead, but cadium, mercury, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated diphenyl ether (PBDE) flame retardants are limited as well.
 





pad


Built-in power status indicator
  • Green LED turns steady on when there is a reliable 12V DC output.
  • LED flashes when there is a problem found by the internal detection circuitry.
  • LED turns off when there is no power output or no power input.

 
Total DC cable length of 1200mm



Models Relationship


Upgrade replacement models for these HIGH POWER models :

HIGH POWER HPA-601250U3 C0-A35
HIGH POWER HPA-601250U3 C0-A34
 HIGH POWER
HPA-501242U3 C0-A4
HIGH POWER
HPA-501242U3 A-9
HIGH POWER
HPA-501242U3 C0-A9 
HIGH POWER
HPA-501242U3 C0-A11
HIGH POWER
HPA-501242U3 C0-A33
HIGH POWER
HPA-501242U3 C0-A34
HIGH POWER
HPA-501242U3 C0-A39 









This web site is powered by
100% wind energy






HIGH POWER  is committed to quality & longevity

         Copyright 2017 HIGH POWER All rights reserved.